Description of Serum Separation Tubes:
1. The wall of the blood collection vessel was silicated and coated with a coagulant to accelerate blood coagulation and shorten the detection time.
2. An inert polymer gel is contained to separate serum from blood clots during centrifugation and prevent serum contamination.
3. Immediately after blood was drawn, the collection vessel was gently mixed 8-10 times upside down to activate coagulation.
4. The tubes were allowed to stand for 30 min or until clots were formed after centrifugation.
Specification of Serum Separation Tubes:
Volume/ml | Size/mm | Additive | Separator | Material | Cap Color | Closure |
1-5 | 13*75 | Clot Activator | Gel | PET/GLASS | Yellow | Safety Cap+Rubber/Rubber Stopper |
6-10 | 13*100 |
What is a separation gel serum tube?
How to separate serum from a yellow separation tube?
When using serum separator tubes, blood should be collected using standard venipuncture techniques. Gently invert the tube 8-10 times to mix the clot activator with the blood. Let the catheter solidify for 20-30 minutes in the vertical position. Centrifuge the tube at approximately 1300-1800 xg for 10-15 minutes. The rpm of the centrifuge will vary depending on the centrifuge and rotor used. A gel barrier forms, separating the serum from the clot.
Why use a yellow serum tube?
1. Serum samples are one of the important samples for biochemical analysis and diagnosis. Serum samples collected by yellow serum tubes can be used to detect many biochemical indicators, such as liver function, renal function, electrolytes, sugars, lipids, etc.
2. Serum samples collected by yellow serum tubes can be stored for a long time and are not easy to deteriorate, which is convenient for subsequent detection.
If you are interested in the product, contact 2bvideo.com for more information for more information
The information of 2bvideo.com limited shown above is provided by the user or collected on the network. Video 2B does not guarantee the authenticity,accuracy and legitimacy of 2bvideo.com limited information. Video 2B does not involve legal relationships and disputes between users arising from transactions other than secured transactions on this website. Disputes shall be settled by you through negotiation. If you are the person in charge or relevant employee of this enterprise, if you find that the enterprise information is incorrect or want to manage thiscompany, please contact us jacklee1558@gmail.com, after you claim the enterprise, you can obtain management permission, publish supplyand demand information, bring consulting orders, and remove page advertisements.
Main Product:
Blood Collection Tube,
Blood Collection Needle,
PRP Tube,
blood bags,
Disposable Medical Supplies,
Safety Syringe