Features
|
|
1
|
Monitors EtCO2, Respiration Rate, display real-time Capnogram within 15 seconds
|
2
|
Pocketsize design fits to pre-hospital, Emergency, Anesthesiology and Respiration
|
3
|
Large numeric display visible from five meters away
|
4
|
24 hours graphic trend can be stored and reviewed
|
5
|
Data management for export and printout via the supplied USB cable
|
6
|
Lithium battery with 6 hours working time and 4 hours charging time
|
7
|
Routine calibration not required
|
8
|
Standard accessories: Bumper, Carry case, Adult/PED adapter, Neonate adapter
|
Technical Specifications
|
|
EtCO2
|
Method: Non-dispersive Infrared Spectroscopy
Range: 0-150mmHg or 0 - 20kPa Accuracy: ±2mmHg, range from 0-40mmHg ±5%, range from 41-70mmHg ±8%, range from 71-100mmHg Update time: Every breath Warm up time:<15 seconds Memory:24 hours with trend and numeric |
Respiration Rate
|
Range: 3 - 150 rpm
Accuracy: ±1% or ±1 rpm whichever is greater Memory: 24 hours with trend and numeric Sensor: Adapter for intubated patient |
Airway Adapter
|
Adult/Pediatric, Neonate
Dead space: 5 ml (adult/pediatric) 1 ml (neonate) |
Power
|
AC input: 100V - 240V, 50Hz/60 Hz
Power consumption: 5W Battery:Lithium battery (3.7V, 1400mAh) Charging time: 4 hours Operating time: 6 hours |
Environment
|
Operating temperature: 5 to 40℃
Operating atmospheric pressure: 86 - 106 kPa Operating humidity:30% - 75% Storage temperature: -20 to +55℃ Storage humidity: <93% Storage atmospheric pressure: 50 - 120 kPa |
Physical Data
|
Dimension: 38(W) x 42(H) x 44(D) mm
Weight: 80g includes battery and adapter |
Language
|
English/ Spanish/ Dutch/ Italian/ French/ Deutsch
|
If you are interested in the product, contact 2bvideo.com for more information for more information
The information of 2bvideo.com limited shown above is provided by the user or collected on the network. Video 2B does not guarantee the authenticity,accuracy and legitimacy of 2bvideo.com limited information. Video 2B does not involve legal relationships and disputes between users arising from transactions other than secured transactions on this website. Disputes shall be settled by you through negotiation. If you are the person in charge or relevant employee of this enterprise, if you find that the enterprise information is incorrect or want to manage thiscompany, please contact us jacklee1558@gmail.com, after you claim the enterprise, you can obtain management permission, publish supplyand demand information, bring consulting orders, and remove page advertisements.
Main Product:
Central Venous Catheter ,
Hemodialysis Catheter,
Peripheral Inserted Central Catheter,
Disposable Interventional accessories,
Blood Pressure Transducer,
Antimicrobial Central Venous Catheter