Ammonia nitrogen and nitrate nitrogen are the most important nitrogen-containing pollutants in water. Due to the increasing serious eutrophication of water bodies, sewage treatment plants have increasingly strict requirements for nitrogen removal. Biological nitrogen removal has become one of the primary considerations in municipal sewage treatment processes. At the same time, from its own perspective, the sewage plant urgently needs to reduce operating costs by reducing fan energy consumption and other means. Therefore, on the premise of meeting the emission standards regulated by regulations, the energy consumption of the blower and the consumption of chemicals can be more accurately controlled to achieve the purpose of controlling operating costs. The DUC2-NH online ammonia nitrogen controller developed and produced by Daruifuno has two SPST relays and two 4-20mA current outputs, which can more accurately control equipment such as blowers and control the ammonia nitrogen content in water quality. This ammonia nitrogen controller is equipped with an ammonia nitrogen sensor using the ion selection method, which is very suitable for process control of denitrification in biological ponds. Usually, the aeration system in a municipal sewage plant uses online monitoring values such as dissolved oxygen, sludge concentration, ammonia nitrogen, and nitrate nitrogen in the biological pool to accurately control the air volume provided by the fan to save energy consumption. A reliable ammonia nitrogen analyzer plays an important role in automatic control.


Specification

Product Name Ammonia nitrogen analyzer
Display Rang 0-1000mg/L
Resolution 0.01mg/L  
Relay Control 2 settable SPST relays with a maximum load of 3A/250VAC
Analog Current Output 2 settable 0/4~20mA active current loop outputs, max load 1000Ω
Communication Method RS485 interface; MODBUS RTU; support JSON
Display Screen 128*64 LCD, adjustable backlight mode, adjustable display rate
Time/Data Record Record 10000 historical data
Operating Temperature 0~60℃,RH<95% ( no condensation)
Shell Material Enhanced ABS
Protection Grade IP66
Dimension 144*144*120mm
Mounting Method Wall mounting, pipe clamping, panel (hole size 138*138 mm)
Power Supply AC: 100~240V 50/60Hz or DC: 18~36V


online ammonia nitrogen analyzer

The basic principle of biological denitrification is to use some specific microbial groups in activated sludge to convert organic nitrogen and ammonia nitrogen in the water into nitrogen gas under a specific environment to ultimately achieve the purpose of denitrification. Biological denitrification consists of three stages. First, ammonifying bacteria convert organic nitrogen in the water into ammonia nitrogen. This process is called ammonification. Secondly, nitrifying bacteria convert ammonia nitrogen into nitrate nitrogen under aerobic conditions, which is called nitrifying process. Finally, during the denitrification process, denitrifying bacteria convert nitrate nitrogen into nitrogen gas under anoxic conditions, allowing it to escape from the water to achieve the purpose of nitrogen removal. The ammonia nitrogen analyzer using the ion selection method is suitable for this method of sewage treatment. There are many methods for detecting ammonia nitrogen, such as Nessler's reagent spectrophotometry, salicylic acid spectrophotometry, titration, etc. Each method has its own advantages. Nessler's reagent spectrophotometry is easy to operate and sensitive. Interfering determinations such as calcium, magnesium, iron and other metal ions, sulfides, aldehydes and ketones, color, and turbidity in water require corresponding preparation treatment. Salicylic acid spectrophotometry is sensitive and stable, and the interference conditions and elimination methods are the same as those of Nessler's reagent spectrophotometry. The electrode method usually does not require pretreatment of water samples and has a wide measurement range. When the ammonia nitrogen content is high, the distillation-acid titration method is generally used.

ammonia nitrogen controller packing



Delfino company focuses on the research, development and production of water quality instruments. Our main products include pH ORP analyzer, conductivity analyzer, turbidity analyzer, COD analyzer, dissolved oxygen analyzer, ammonium analyzer, chlorine analyzer, etc. This online ammonia nitrogen controller combined with NH351 ammonia nitrogen sensor is an electrochemical method using ionophores. A significant advantage of this method is that it greatly reduces the size of the analysis equipment. Ammonia nitrogen data can be obtained in real time through a sensor and controller. The cost is lower than that of traditional wet chemical analyzers, and it can be used on a large scale in sewage plants and other occasions. use. If you are interested in our ammonia nitrogen controller, please contact us.

Contact Now

If you are interested in the product, contact 2bvideo.com for more information for more information

To:
Suzhou Delfino Environmental Technology Co., Ltd.
Message:
Submit
Disclaimer:

The information of 2bvideo.com limited shown above is provided by the user or collected on the network. Video 2B does not guarantee the authenticity,accuracy and legitimacy of 2bvideo.com limited information. Video 2B does not involve legal relationships and disputes between users arising from transactions other than secured transactions on this website. Disputes shall be settled by you through negotiation. If you are the person in charge or relevant employee of this enterprise, if you find that the enterprise information is incorrect or want to manage thiscompany, please contact us jacklee1558@gmail.com, after you claim the enterprise, you can obtain management permission, publish supplyand demand information, bring consulting orders, and remove page advertisements.

Audited supplier
2 year
Address: Suzhou, China


Main Product: pH/ORP Meter, Conductivity Meter, Dissolved Oxygen Meter, Turbidity Meter, Multiparameter Analyzer, COD Sensor

Disclaimer:
The information of 2bvideo.com limited shown above is provided by the user or collected on the network. Video 2B does not guarantee the authenticity,accuracy and legitimacy of 2bvideo.com limited information. Video 2B does not involve legal relationships and disputes between users arising from transactions other than secured transactions on this website. Disputes shall be settled by you through negotiation. If you are the person in charge or relevant employee of this enterprise, if you find that the enterprise information is incorrect or want to manage thiscompany, please contact us jacklee1558@gmail.com, after you claim the enterprise, you can obtain management permission, publish supplyand demand information, bring consulting orders, and remove page advertisements.
Content Us