Get Quote
730 people are quoting
X

Portable X-ray video

3 year ago
52 0
Product details
The XR-01 Dental Portable X-Ray System is intended to be used by trained dentists and dental technicians as an extraoral x-ray source for producing diagnostic x-ray images using intraoral image receptors. Its use is intended for both adult and child subjects

Rolence Dental Portable X-Ray system XR-01 is designed for use in radiography to find hidden dental structures, malignant or benign masses, bone loss, cavities and other areas of dental diagnosis. The controlled x-ray beam penetrates oral structures at different levels, which depending on varying anatomical densities, and then exposures onto image receiver such as film or Dental Digital Sensor to form a radiography image.

The owner/operator is responsible for verifying continued compliance exposure rates, leakage radiation, alignment of the useful beam, and the calibration of kVp and mAs. Annual verification by a qualified service technician may be required by federal law. Compliance with applicable statutory and regulatory requirements is the responsibility of the owner/operator. Consult local, state, and/or federal agencies regarding specific requirements and regulations applicable to the use of this type of medical electronic equipment.

Ensure the adaptor of Dental Portable X-Ray is unplugged before attempting to clean. To make sure that power is off while cleaning. Use a non-alcohol based disinfectant only - wipes or a cloth dampened with liquid or spray. The system is not designed to be subjected to any kind of sterilization procedure and not designed to be used to sterilize anything else.

Observe the following safety procedures to avoid electric shock or serious injury to operators and patients and to avoid system malfunction.
● Under no circumstance should the safety interlocks in the system be bypassed, jumped, or otherwise disabled.
● Under no circumstance should the system or assembly covers be removed by anyone other than a Rolence trained service representative.
● Do not place food or beverage containers on any part of the equipment. They can trip over and introduce conductive substances into the electrical circuitry.

NOTE: The system of Rolence Dental Portable X-Ray is not waterproof. Water, soap, or other liquids, if allowed to drip into the equipment, can cause electrical short circuits leading to electric shock and fire hazards. If liquids should accidentally spill into the system electronics, do not connect the power cord to a supply connection or turn the system on until the liquids have dried or evaporated completely.

The user should develop an emergency procedure for the area in which the system is used that includes the following safety measures:
● Turn the system off and unplug the main power cable from the outlet.
● Evacuate everyone from the area.
● Call for help.
● Use only a fire extinguisher of a type approved for electrical fires.

NOTE: The use of the wrong type of fire extinguisher presents electrical shock and burn hazards. To avoid these hazards, a fire extinguisher which has been approved by the appropriate local, state, and federal codes must be available in the room where Dental Portable X-Ray is being used.

This X-Ray tube assembly produces ionizing radiation when energized. Hence, when, used, it can be better that the authorized operators wear X-ray Protective devices like X-Ray protective apron, glove or thyroid cover, etc.
It is imperative that the owner designates areas suitable for safe operation and service of the system and operator ensure that it is used only in these designated areas.
It is the responsibility of the owner to ensure that all personnel wear protective clothing and radiation monitoring devices while using this system.

Contact Now

If you are interested in the product, contact 2bvideo.com for more information for more information

To:
Rolence Enterprise Inc.
Message:
Submit
Disclaimer:

The information of 2bvideo.com limited shown above is provided by the user or collected on the network. Video 2B does not guarantee the authenticity,accuracy and legitimacy of 2bvideo.com limited information. Video 2B does not involve legal relationships and disputes between users arising from transactions other than secured transactions on this website. Disputes shall be settled by you through negotiation. If you are the person in charge or relevant employee of this enterprise, if you find that the enterprise information is incorrect or want to manage thiscompany, please contact us jacklee1558@gmail.com, after you claim the enterprise, you can obtain management permission, publish supplyand demand information, bring consulting orders, and remove page advertisements.

Audited supplier
3 year
Address: Chungli, China Taiwan


Main Product: Portable X-Ray, Curing Light, Ultrasonic Scaler, Curing Box , Dental Digital Sensor, UV Spot Curing

Disclaimer:
The information of 2bvideo.com limited shown above is provided by the user or collected on the network. Video 2B does not guarantee the authenticity,accuracy and legitimacy of 2bvideo.com limited information. Video 2B does not involve legal relationships and disputes between users arising from transactions other than secured transactions on this website. Disputes shall be settled by you through negotiation. If you are the person in charge or relevant employee of this enterprise, if you find that the enterprise information is incorrect or want to manage thiscompany, please contact us jacklee1558@gmail.com, after you claim the enterprise, you can obtain management permission, publish supplyand demand information, bring consulting orders, and remove page advertisements.
Content Us