Modular digital clamp-on flowmeter and clamp-on ultrasonic flow meter for flowmeter clamp on1

3 year ago
83 0
Product details

The ultrasonic flowmeter adopts a non-contact measurement method, which is accurate and reliable. It can be continuously measured for a long time.

Product details

I. Overview

Ultrasonic flowmeter is a combination of flow measurement technology and low-cost toilet, which can be directly installed at the measuring point. The flow of the ultrasonic flowmeter has no moving parts and needs no daily maintenance. The microprocessor on the instrument provides accurate digital signal coding and cross-correlation detection procedures, which can provide long-term drift-free measurement. The measurable fluid is almost all clean and uniform liquid.

2. Application

(1). Drinking water, River water, sea water, groundwater, cooling water, high temperature water and sewage;

(2). Lubricating oil, diesel oil and fuel oil;

(3). Chemical liquids;

(4). Other homogeneous fluids.

3. Characteristics

(1). Various power supply modes: a single 3.6V lithium battery can work for 6 years, using two-wire system of 4-20mA, RS232, RS485 output type, and can work normally without batteries;

(2). The measurement content is rich: it can display accumulative flow, accumulative heat, instantaneous flow, instantaneous heat, supply and return water temperature, current temperature difference, fault operation time, working state, date, time, etc.

(3). High level of protection: protection level can reach IP68, can be immersed in underwater 2 meters work;

(4). Structural firmness: The measuring pipe section adopts precision casting technology, no leakage, no pressure loss and movable parts, 10 years maintenance-free design.

(5). Humanized design: magnetic rod operation, internal double keys, easy to operate; fault self-diagnosis.

(6). Ordinary metal pipes such as carbon steel, stainless steel, cast iron, copper, aluminium, etc.

(7). Other non-metallic pipelines such as PVC, PR, FRP, cement and other pipelines.

ITEM

Description

Main unit

Accuracy

Better than ±1%

Repeatability

Better than 0.2%

Measurement

Period

500ms

Display

LCD with backlight, display accumulated flow/heat, instantaneous flow/heat, velocity, time etc.

Output

Analogue output: 4-20mA or 0-20mA current output. Impedance 0~1kW. Accuracy 0.1%.

OCT output: Frequency signal (1~9999HZ)

Relay output: over 20 source signal (no signal, reverse flow etc.)

RS485 serial port

 

Input

Three analogue input

Three-wire PT100 resistor input (optional)

Other functions

Automatically record the totaliser data of the last 64 days / 64 months / 5 years;

The power-on time and corresponding flow rate of the last 64 power on and off events. Allow manual or automatic flow loss compensation

The instrument working status of the last 64 days

pipe

material

Steel, stainless steel, cast iron, cement pipe, copper, PVC, aluminum, FRP etc. Liner is allowed

Size

15-6000mm

Straight pipe section

In the upstream it must be beyond 10D, in the downstream it must be beyond 5D, in the upstream the length must be beyond 30D from the access of the pump. (D stands for pipe diameter)

Liquid

Types

Water, sea water, industrial sewage, acid & alkali liquid, alcohol, beer, all kinds of oils which can transmit ultrasonic single uniform liquid

Temperature

Standard: -30℃ - 90℃ ,High-temperature:-30℃ - 160℃

Turbidity

Less than 10000ppm, with a little bubble

 

Flow Direction

Bi-directional measuring, net flow/heat measuring

Environment

Temperature

Main Unit: -30℃ - 80℃

Transducer: -40℃ -110℃, Temperature transducer: select on enquiry

Humidity

Main Unit: 85% RH

Transducer: water-immersible, water depth less than 3m

Cable

Twisted Pair Line, standard length of 20m, can be extended to 500m (not recommended); Contact the manufacturer for longer cable requirement.

RS-485 interface, transmission distance up to 1000m

Power Supply

DC24V or AC220v

Power Consumption

Less than 1.5W

Protocols

MODBUS, M-BUS, Fuji extended protocol and other factory protocol


 
 
 

Ultrasonic FlowmeterModular digital clamp-on flowmeter and clamp-on ultrasonic flow meter for flowmeter clamp on

Packaging & Shipping

Modular digital clamp-on flowmeter and clamp-on ultrasonic flow meter for flowmeter clamp on







Company Information
Modular digital clamp-on flowmeter and clamp-on ultrasonic flow meter for flowmeter clamp on






























 

 

Contact Now

If you are interested in the product, contact 2bvideo.com for more information for more information

To:
Wuxi Winsun Automation Instrument Co., Ltd
Message:
Submit
Disclaimer:

The information of 2bvideo.com limited shown above is provided by the user or collected on the network. Video 2B does not guarantee the authenticity,accuracy and legitimacy of 2bvideo.com limited information. Video 2B does not involve legal relationships and disputes between users arising from transactions other than secured transactions on this website. Disputes shall be settled by you through negotiation. If you are the person in charge or relevant employee of this enterprise, if you find that the enterprise information is incorrect or want to manage thiscompany, please contact us jacklee1558@gmail.com, after you claim the enterprise, you can obtain management permission, publish supplyand demand information, bring consulting orders, and remove page advertisements.

Audited supplier
3 year
Address: Wuxi, China


Main Product: Vibration Transmitter, Pressure Transmitter, Level Transmitter , Electromagnetic Flowmeter, Temperature Transmitter , Radar Level Transmitter

Disclaimer:
The information of 2bvideo.com limited shown above is provided by the user or collected on the network. Video 2B does not guarantee the authenticity,accuracy and legitimacy of 2bvideo.com limited information. Video 2B does not involve legal relationships and disputes between users arising from transactions other than secured transactions on this website. Disputes shall be settled by you through negotiation. If you are the person in charge or relevant employee of this enterprise, if you find that the enterprise information is incorrect or want to manage thiscompany, please contact us jacklee1558@gmail.com, after you claim the enterprise, you can obtain management permission, publish supplyand demand information, bring consulting orders, and remove page advertisements.
Content Us