Purpose of Verabar flowmeter
Verabar flow meters are suitable for high-precision flow measurement of gases, liquids and steam. The Verabar flowmeter is a differential pressure, rate average flow sensor that measures flow through the differential pressure generated by the sensor in the fluid. The Verabar flowmeter reflects the true flow rate of the fluid, with an accuracy of ± 1.0 and a repeatability of ± 0.1. The outstanding advantage of Verabar is that it outputs a very stable, pulsation-free differential pressure signal.
The probe with a bullet cross-section shape can produce precise pressure distribution and a fixed fluid separation point; the low-pressure pressure tapping holes located on both sides of the probe and in front of the fluid separation point can generate a stable differential pressure signal and effectively prevent blockage. The internal integrated structure can avoid signal leakage, improve the structural strength of the probe, and maintain long-term high accuracy.
Verabar probe anti-clogging design
With its excellent anti-clogging design, the Verabar flow probe completely gets rid of the shortcomings of plug-in flow probes such as Annubar that are prone to clogging, making the anti-clogging level of the velocity-averaging tube flow probe reach an unprecedented level.
The high-pressure tapping hole of the probe will not be blocked. The front of the probe forms a high-pressure area. The pressure is slightly higher than the static pressure of the pipeline, preventing particles from entering. Please note: the velocity of the fluid at the high-pressure tapping hole of the probe is zero and no objects will enter the pressure tapping hole. When starting up, the fluid enters the elbow under the action of the static pressure of the pipe, and a pressure balance state is quickly formed. When the pressure equilibrium state is formed, the fluid encounters high pressure at the entrance of the elbow and takes a detour instead of entering the elbow.
The low-pressure hole of the Verabar flowmeter is essentially anti-blocking. Under normal circumstances, dust, sand and particles are concentrated at the rear of the probe under the action of vortex forces. This is why autumn foliage is always concentrated behind houses in the lee. For other probes, the low-pressure tapping hole is located in the vacuum area at the tail of the probe. Under the action of vortex force, the low-pressure tapping hole of the probe is quickly blocked by impurities brought by the eddy current. The unique design of the Verabar flowmeter places the low-pressure tap holes on both sides of the rear side of the probe, at the fluid separation point and in front of the wake area. This design inherently prevents clogging and produces a very stable low voltage signal.
If you are interested in the product, contact 2bvideo.com for more information for more information
The information of 2bvideo.com limited shown above is provided by the user or collected on the network. Video 2B does not guarantee the authenticity,accuracy and legitimacy of 2bvideo.com limited information. Video 2B does not involve legal relationships and disputes between users arising from transactions other than secured transactions on this website. Disputes shall be settled by you through negotiation. If you are the person in charge or relevant employee of this enterprise, if you find that the enterprise information is incorrect or want to manage thiscompany, please contact us jacklee1558@gmail.com, after you claim the enterprise, you can obtain management permission, publish supplyand demand information, bring consulting orders, and remove page advertisements.
Main Product:
Electromagnetic Flowmeter,
Vortex Flowmeter,
Level Gauge,
Turbine Flowmeter,
Pressure Transmitters ,
Magnetic Flap Level Gauge